Infusion Set Positive Pressure Leakage Tester

Infusion Set Positive Pressure Leakage Tester

The Infusion Set Positive Pressure Leakage Tester is a dedicated testing instrument developed in accordance with relevant national medical device standards for evaluating the positive pressure leakage performance of infusion sets. The system integrates intelligent control, force measurement, displacement measurement, and data output functions, providing a stable and standardized solution for leakage testing. With a user-friendly interface and clear parameter display, the tester ensures efficient and repeatable quality inspection for disposable infusion devices.

Application

This tester is designed for positive pressure leakage testing of medical infusion devices during quality control and compliance verification.

Typical application scenarios include:

Positive pressure leakage testing of disposable infusion sets

Quality inspection of gravity-type infusion devices

Incoming inspection and batch testing in medical device manufacturing

Type testing and routine verification in testing laboratories

Compliance testing during product development and certification

Applicable test products include disposable infusion sets and related fluid delivery components.

Standards

The Infusion Set Positive Pressure Leakage Tester complies with the following medical device standard:

GB 8368-2018 (Disposable infusion sets for single use, gravity feed)

Parameters

Parameter Specification
Positive Pressure Output Range 120 kPa–160 kPa (adjustable), LED digital display, accuracy within ±5%
Positive Pressure Holding Performance Pressure drop shall not exceed 1 kPa within 3 minutes
Test Duration 1 s–60 s (adjustable), LED digital display, accuracy within ±1 s
Pressure Range 0–69 kPa
Time Setting Range 0–999 s
Power Consumption 200 VA
Display Type 320 × 240 monochrome LCD, full Chinese window interface
Control Method Keyboard control for menu navigation and on-screen keypad operation
Operating Temperature 5–40 °C
Relative Humidity 45–80%
Power Supply Voltage 220 V ±22 V
Power Frequency 50 Hz ±1 Hz
Equipment Classification Class I, Type B

Features

Standard-oriented design

Developed specifically to meet the positive pressure leakage test requirements defined in national medical device standards.

Integrated intelligent control system

The built-in CPU, mainboard, LCD display, and keyboard enable stable control and precise parameter setting.

Clear and intuitive operation

Full-window Chinese interface with menu-driven operation allows straightforward use without specialized training.

Stable pressure control and monitoring

Adjustable positive pressure output with digital display ensures consistent test conditions and reliable leakage detection.

Compact and functional structure

Combines control, measurement, and data output functions in a single, practical testing unit.

Accessories

Power cable

Built-in printer

Drain outlet connector

Operation manual

Test Procedures

Place the instrument horizontally on a stable testing bench.

Install the test specimen securely onto the drain outlet connector.

Connect the power plug to the distribution board, ensuring reliable grounding of the power socket.

Power on the instrument and set the required positive pressure and test duration via the control panel.

Start the test and observe pressure stability during the test period.

Record or print the test results as required after test completion.

Maintenance Information

Regularly inspect pressure connections and sealing components to prevent leakage.

Keep the display screen and control panel clean and free from moisture.

Verify pressure accuracy periodically to maintain compliance with test requirements.

Ensure the power supply grounding is reliable before each operation.

Store the instrument in a clean, dry environment when not in use.

FAQ

1. What is the core advantage of this product?

Its main advantage lies in standardized positive pressure leakage testing specifically designed for disposable infusion sets in accordance with medical device regulations.

2. Are the test results reliable?

Yes. Stable pressure control, accurate timing, and defined pressure-holding requirements ensure consistent and repeatable test results.

3. Which international or industry standards does it comply with?

The tester complies with GB 8368-2018 for disposable gravity-type infusion sets.

4. Why is this product important?

Positive pressure leakage testing is critical for ensuring the safety and reliability of infusion devices, directly impacting patient safety during clinical use.

5. Which fields is this product suitable for?

It is suitable for medical device manufacturing, quality inspection laboratories, regulatory testing institutions, and product development environments for infusion devices.


Note:QINSUN is very in place for textile testing and quality control,we have our own textile testing lab. Our textile testing equipment and testing methods are in the leading position in the industry. We have passed the textile testing certification and iso textile testing standards issued by a number of testing,We can provide textile testing equipment pdf manual. Sufficient inventory, big discounts, limited time promotion, Order now!

Leave Message Get Price