High and Low Temperature Flow Resistance Test Bench

1. Overview
The High and Low Temperature Flow Resistance Test Bench (hereinafter referred to as the “test bench”) is primarily designed for highand low-temperature flow resistance testing of transmission filters (pressure-fed / suction-fed filters).
1.1 Reference Standards
(1) GB/T 17486-2006 Hydraulic Filters – Evaluation of Pressure Drop vs. Flow Characteristics
(2) ISO 3968:2017 Hydraulic Filters – Evaluation of Pressure Drop vs. Flow Characteristics
1.2 Technical Features
(1) The system is operated via a mouse and keyboard. Pressure–time curves are displayed in real time during testing, and test data are saved upon completion.
(2) The test bench frame adopts a sheet-metal structure, offering high structural strength and an aesthetically pleasing appearance. An integrated layout is adopted, featuring a rational structure and arrangement for convenient maintenance.
(3) The equipment is designed in accordance with ergonomic principles, with a well-developed structure that facilitates operation and maintenance.
(4) Sufficient operating space is provided around the specimen mounting area, allowing tested products to be installed conveniently, quickly, and securely.
(5) Overpressure and overtemperature protection functions are provided to ensure safety throughout the testing process.
1.3 Test Specimens
(1) Negative-pressure transmission filters
(2) Positive-pressure transmission filters (spin-on filters and positive-pressure filters with outlets located inside the oil tank)
1.4 Test Item
High- and low-temperature flow resistance test
2. Main Technical Specifications
No. | Technical Parameter | Technical Specification | Remarks |
1 | Working Medium | Transmission Oil | Provided by Party A |
2 | Medium Temperature | -40°C to 150°C (Temperature Sensor Measurement Accuracy: Class A, ±0.5°C) | |
3 | Temperature Control Accuracy | ±2°C (Based on Oil Tank Temperature) | |
4 | Maximum Negative Pressure | -40 kPa (Differential Pressure Sensor Measurement Accuracy: 0.1%) | |
5 | Maximum Positive Pressure | 2 MPa (Differential Pressure Sensor Measurement Accuracy: 0.1%) | |
6 | Maximum Flow Rate | 80 L/min (Flow Sensor Measurement Accuracy: 1%); Flow Rate at -40°C: Up to 10 L/min | |
7 | Viscosity Range | 2–9000 cSt | |
8 | Test Station | 1 | |
9 | Oil Tank Capacity | 50 L | Subject to the jointly approved drawings |
10 | Equipment Power Supply | AC 380 V / 50 Hz | |
11 | Power Cable Length | 5 m | |
12 | Facility Requirements | Facility Cooling Water | |
13 | Total Equipment Power | 50 kW | |
14 | Main Unit Dimensions | 2700 × 1600 × 2200 (L × W × H) mm | Subject to the jointly approved drawings |
15 | Integrated Heating and Cooling Unit Dimensions | 2500 × 1800 × 2100 (L × W × H) mm | Subject to the jointly approved drawings |
16 | Piping Material | 304 Stainless Steel | |
17 | Equipment Weight | 2000 kg | Subject to the jointly approved drawings |
3. Working Principle
Figure 3.1 Hydraulic System Schematic
1.Temperature Sensor 2.Insulated Oil Tank 3.Y-Type Strainer 4.Differential Pressure Sensor
5.Gear Pump 6.Check Valve 7.Gear Pump 8.Check Valve 9.Pneumatic Three-Way Ball Valve
10.Filter 11.Flow Meter 12.Differential Pressure Sensor 13.Ball Valve
14.Heating and Cooling Integrated Unit
4. Design Description
The test bench mainly consists of the test system, electrical control system, integrated heating and cooling unit, and other components.
Figure 4.1 Schematic Diagram of the Test Bench Appearance
4.1 Test System
The test system mainly consists of an insulated oil tank, gear pump, temperature sensors, differential pressure sensors, screw flow meter, and other components.
The test bench adopts an enclosed structural design, with a frame fabricated from welded square steel tubes and an external protective cover. The overall structure is manufactured using sheet metal fabrication techniques and finished with a powder coating, providing high structural strength and an attractive appearance. A pull-out oil collection tray is installed at the bottom to effectively prevent environmental pollution caused by oil spills, splashes, drips, and leaks. The pull-out design also facilitates cleaning and maintenance.
The test bench is equipped with heavy-duty casters featuring locking and height-adjustment functions, allowing flexible movement while enabling the bench to be securely locked in place and leveled.
Insulated Oil Tank
The insulated oil tank is constructed of double-layer 304 stainless steel, with the space between the layers filled with thermal insulation material. The tank is equipped with a level sensor and a temperature sensor to monitor the oil condition in real time.
Figure 4.2 Schematic Diagram of the Oil Tank Appearance
Gear Pump
The selected gear pump provides power for the system. The pump has a maximum operating pressure of up to 2 MPa and is characterized by low vibration, long service life, and stable performance.
Large Pump Displacement: 63 mL/rev
Small Pump Displacement: 25 mL/rev
Maximum Pressure: 2 MPa
Maximum Fluid Viscosity: 9,000 cSt
Operating Temperature: -40°C to 150°C
Figure 4.3 Schematic Diagram of the Pump Appearance
Temperature Sensor
A Class A standard temperature sensor is installed in the oil tank to monitor the oil temperature.
The technical specifications of the temperature sensor are as follows:
Output: PT100
Measurement Range: -50°C to 200°C
Accuracy Class: Class A
Figure 4.4 Schematic Diagram of the Temperature Sensor Appearance
Differential Pressure Sensor
The differential pressure sensor integrates a differential pressure sensing chip within the positive and negative pressure chambers of the sensor. Pressure is introduced through the two pressure ports and applied to the sensing chip, which generates a linear voltage output. Combined with a dedicated digital circuit, the signal undergoes processing such as amplification, linear compensation, anti-interference, and surge protection, resulting in a standard industrial signal output.
The sensor features high accuracy, stable performance, and strong anti-interference capability. Its appearance and technical specifications are as follows:
Measurement Range: 0–100 kPa, 0–2 MPa
Output Signal: 4–20 mA
Accuracy: ±0.1% FS
Operating Temperature: -50°C to 80°C
Figure 4.5 Schematic Diagram of the Differential Pressure Sensor Appearance
Screw Flow Meter
The screw flow meter features strong anti-interference capability, accurate measurement, and high stability.
Measurement Range: 1–150 L/min
Output Signal: 4–20 mA
Accuracy: ±1% FS
Operating Temperature: -40°C to 150°C
Figure 4.6 Schematic Diagram of the Flow Meter Appearance
4.2 Electrical Control System
The electrical control system mainly consists of two parts: hardware and software. All system hardware components are selected from well-known industry brands, offering a wide range of applicable operating conditions and reliable operation.
The control system adopts a touchscreen combined with PLC control, featuring a user-friendly human-machine interface, simple operation, and stable performance. It also enables real-time display and recording of relevant test data.
Industrial PC
The industrial PC selected for this equipment is specifically designed for mission-critical applications. It is equipped with a high-efficiency 300 W ATX power supply with power factor correction (PFC) and two easily maintainable cooling fans. System status LED indicators on the front panel of the chassis display the operating status of the power supply, hard drive, and system voltages.
Figure 4.7 Schematic Diagram of the Industrial PC Appearance
Programmable Logic Controller (PLC)
The PLC is equipped with a dedicated high-speed processor chip, with a basic instruction execution time of up to 0.08 μs, significantly outperforming other PLCs in the same class. Its powerful capabilities enable the implementation of complex control functions, whether operating independently or connected to a network. Its outstanding features include the following:
Modules with various performance specifications can effectively meet and adapt to different automation control requirements.
A simple and practical distributed architecture with multi-interface networking capabilities.
A wide range of freely expandable modules.
The I/O terminal block can be easily removed as a complete unit. Designed for demanding control systems, the PLC provides more input/output points, greater module expansion capabilities, faster processing speeds, and more powerful integrated special functions. It can fully meet the requirements of complex industrial field control systems.
Figure 4.8 Schematic Diagram of the PLC Appearance
Software System
The operation software features a simple and intuitive interface and can automatically execute operations according to preset parameters. It provides real-time display of system operating conditions, including temperature, flow rate, and pressure, and records test data throughout the testing process.
The control system is equipped with an alarm interface and corresponding safety protection measures. It can trigger alarms in the event of abnormalities, display common error causes, and issue alarms when pressure, temperature, or flow rate exceeds the specified limits during operation.
The operation software is independently developed by our company and offers stable performance, with ongoing software upgrades and bug-fixing services.
4.3 Integrated Heating and Cooling Unit
The selection of the integrated heating and cooling unit is of critical importance. The unit selected for this project has been validated through practical application in previous projects and demonstrates stable performance. It offers a temperature control accuracy of ±2°C and a temperature control range of -40°C to 150°C.
Leave Message Get Price