Flow Fatigue and Burst Resistance Test Bench

1.Overview
The Flow Fatigue and Burst Resistance Test Bench(hereinafter referred to as the“test bench”)is mainly used for flow pulse fatigue tests and collapse(burst)resistance tests of filter elements.
The flow pulse fatigue test is conducted by adding specific particulate contaminants to the test system until the filter element reaches the predetermined maximum differential pressure.The filter element is then subjected to a fatigue resistance test under a consistent alternating flow rate.
The collapse(burst)resistance test is conducted by continuously injecting powder into the system to gradually increase the pressure drop across the filter element until the filter element collapses(bursts),or until the predetermined maximum pressure drop is reached without collapse(burst).
1.1 Design Basis
The test bench is designed in accordance with GB/T 17488—2008,Hydraulic Fluid Power—Filter Elements—Determination of Resistance to Flow Fatigue Using Particulate Contaminants.
1.2 Test Items
(1)Resistance to flow fatigue of filter elements(flow pulse test)
(2)Collapse(burst)resistance test of filter elements
1.3 Referenced Documents
(1)GB/T 786.1-2021 Fluid Power Systems and Components—Graphical Symbols and Circuit Diagrams—Part 1:Graphical Symbols
(2)GB/T 3766-2015 Hydraulic Fluid Power—General Rules and Safety Requirements for Systems and Their Components
(3)GB/T 7935-2005 Hydraulic Fluid Power Components—General Technical Specifications
(4)GB/T 5226.1-2019 Electrical Safety of Machinery—Electrical Equipment of Machines—Part 1:General Requirements
(5)GB/T 17486-2006 Hydraulic Fluid Power—Filters—Evaluation of Pressure Drop/Flow Characteristics
(6)GB/T 17488—2008 Hydraulic Fluid Power—Filter Elements—Determination of Resistance to Flow Fatigue Using Particulate Contaminants
(7)GB/T 14041.3—2010 Hydraulic Fluid Power—Filter Elements—Part 3:Method for Testing Collapse(Burst)Resistance
1.4 Technical Features
(1)The test bench adopts an enclosed design.The frame is made of industrial-grade,high-strength aluminum alloy profiles.It features strong corrosion resistance,light weight,high strength,a compact structure,an attractive appearance,and easy maintenance.
(2)The panels and work surface of the test chamber are made of 304 stainless steel.The protective door panels and observation side panels are made of tempered glass,providing protection while allowing the test specimen to be observed at any time.The top of the test chamber is also made of tempered glass and is equipped with a light source to ensure good interior illumination.
(3)The system oil tank and pipelines are made of 304 stainless steel.Based on years of experience,the system structure has been continuously optimized to keep particulate matter in a turbulent,suspended state within the system.The equipment is equipped with a patented particulate dispersion device,which further ensures the stable suspension of particulate matter in the system.The overall testing stability and accuracy of the equipment are at the leading level in the industry.
(4)The high-concentration contaminant injection metering pump used in the system was specially developed by our company for efficiency test benches.It features high strength,good wear resistance,stable long-term operation,and high output accuracy.
(5)The system features a user-friendly human-machine interface and a high degree of automation.During testing,it displays the main filter test parameters in real time,including pressure,flow rate,temperature,and differential pressure.It also displays the time-pressure-drop curve in real time,supports one-touch test startup,and automatically generates a test report upon completion.
(6)The test bench is equipped with comprehensive safety protection measures,including mechanical protection and electrical alarm interlocking functions,effectively ensuring the safety of personnel and equipment.The system provides phase-sequence protection,electrical interlocking,overtemperature and overpressure protection,and liquid-level safety protection.It can also display corresponding alarm messages to facilitate troubleshooting.
2.Main Technical Specifications
2.1 Operating Environment Conditions
(1)Ambient temperature:0°C–40°C;
(2)Ambient humidity:20%–70%;
(3)Power supply:AC 380V/50Hz.
2.2 Main Technical Specifications
No. | Technical Parameter | Technical Specification | Remarks |
1 | Test medium | L-HM 32 or oil specified by the customer | |
2 | Test dust | ISO 12103-1,A2/A3 dust | |
3 | Medium temperature | Room temperature to 60±2°C | |
4 | Test flow rate range | 10–180 L/min | Class 0.15 |
5 | System pressure | 3.0 MPa | |
6 | Differential pressure sensor | 2500 kPa | Class 0.1 |
7 | Flow switching frequency | 0.2–1 Hz | |
8 | Contaminant injection flow rate | 50–200 mL/min | |
9 | Control mode | Automatic program control | |
10 | Heating method | Electric heating | |
11 | Cooling method | Water cooling | Chiller available as an optional accessory |
12 | Test bench power | 14 kW | |
13 | Test bench power supply | Three-phase,five-wire system,AC 380V/50Hz | |
14 | Test bench air supply | 130 NL/min,≥0.6 MPa | |
15 | Test bench dimensions | 3200×1500×2000(L×W×H)mm | Subject to the countersigned drawings |
16 | Equipment weight | 1.5 t |
3. Working Principle
1.Agitator assembly | 10.Contaminant injection circulation pump | 19.Injection port | 28Pressure sensor |
2.Contaminant injection oil tank | 11.Heat exchanger | 20.Quick connector | 29Hydraulic pump station |
3.Heating belt | 12.Cooling valve | 21Test specimen | 30Purification filter |
4.Sampling valve | 13.Injection pump | 22Throttle valve | 31Flow meter |
5.Check valve | 14.Injection port | 23Heat exchanger | 32Proportional relief valve |
6.Three-way ball valve | 15.Check valve | 24Three-way valve | 33Test pump |
7.Filter | 16.Pressure sensor | 25Purification filter | 34Test oil tank |
8.Liquid level gauge | 17.Three-way valve | 26Check valve | 35Circulation pump |
9.Thermometer | 18.Proportional directional valve | 27Differential pressure sensor | 36Heat exchanger |
4.Design Description
The test bench mainly consists of an equipment frame,test circulation system,contaminant injection system,real-time temperature control system,and electrical control system.
4.1 Equipment Frame
The equipment frame adopts an enclosed structural design.Its main structure is made of high-strength industrial aluminum alloy profiles,while the test panels and work surface are made of 304 stainless steel plates.
The operating chamber is equipped with a protective door fitted with tempered glass,making it convenient to observe the real-time operating condition of the test specimen.
Heavy-duty Fuma casters are installed at the bottom of the equipment frame,allowing the equipment to be moved flexibly,fixed in position,and adjusted for levelness.
The equipment is designed with a movable oil collection tray,which collects oil resulting from running,overflowing,dripping,or leaking and can be easily pulled out for cleaning.
4.2 Test Circulation System
The test circulation system mainly consists of pipe fittings and connectors,a test oil tank,a test pump,a proportional relief valve,purification filters,a servo valve,a hydraulic station,and measurement and control components.It provides the test specimen with the pressure and flow rate parameters required for testing.
(1) Pipes and Connectors:The test pipelines and pipe fittings are made of 304 precision stainless steel tubes,with a pressure design margin of≥1.2 times.The inner surfaces of the pipelines are smooth,effectively preventing particulate matter from adhering to them.The pipeline structure is designed to keep the oil in a turbulent state while minimizing dead corners where particulate matter may accumulate.Pipe connections use standard compression-type fittings or flat-face sealed connections.The arrangement of pipe
connectors and pipelines avoids flow dead zones,effectively preventing the accumulation of particulate matter.
(2) Test Oil Tank:The test oil tank is made of 304 stainless steel and adopts a conical-bottom design with a cone angle not exceeding 90°.This effectively prevents contaminants from settling in the oil tank and ensures that the return oil disperses below the liquid surface.A liquid-level sensor is also installed to monitor the oil level.
(3) Test Pump Assembly:The test pump assembly uses an aviation-grade gear pump that has undergone special design and treatment,significantly improving its resistance to hard particles while reducing its influence on the particle size distribution of contaminants.The test pump assembly is driven by a variable-frequency motor,providing high flow rate adjustment accuracy,good stability,and low flow pulsation.
(4) Purification Filter:A high-precision purification filter is used,achieving a filtration efficiency of 99%for particles measuring 4μm.It enables the system cleanliness level to reach the required standard quickly and features a large contaminant-holding capacity and long service life.The filter is equipped with an alarm indicator device that provides an alarm when the filter element reaches the end of its service life,indicating that replacement is required.
(5) Heat Exchanger:A brazed plate heat exchanger is selected.This type of heat exchanger is a new,highly efficient heat exchange device made by stacking a series of thin metal plates with corrugated patterns and joining them through brazing.The cooling and heating media flow in opposite directions through adjacent internal channels to exchange heat.It features high heat exchange efficiency and a high pressure-resistance rating.
(6) Proportional Relief Valve:A pilot-operated proportional relief valve is selected to regulate the pressure at the pump outlet and the servo valve inlet,ensuring flow stability in the flow pulsation test system.
(7) Directional Valve:The hydraulic system uses a proportional directional valve.The pilot valve uses an external oil supply and external oil drainage arrangement.The direction of the valve is controlled by pilot fluid pressure,enabling it to meet the switching frequency and response speed requirements of high-flow pulse testing.
(8) Hydraulic Station:The hydraulic station mainly provides power for the pilot valve body of the electro-hydraulic directional valve.Its rated pressure is 3 MPa,rated flow rate is 16 L/min,and power is 0.75 kW.It can quickly meet the response requirements of the electro-hydraulic directional valve.
(9) Pressure and Differential Pressure Sensors:The sensors use imported chips.Their performance specifications comply with the requirements of GB/T 18853.The accuracy can reach up to±0.075%.They offer stable performance and a long service life.The process-wetted material is 316L stainless steel,which is resistant to contamination.The differential pressure sensor supports the HART protocol,making adjustment and configuration convenient and quick.
(10) Flow Meter:A mass flow meter is selected.The mass flow meter operates based on the principles of motion mechanics.When the process fluid enters the sensor,the fluid is divided.During measurement,the drive coils excite the tubes to vibrate in opposite directions at their natural resonant frequency.When the tubes vibrate,the voltage generated by each sensor forms a sine wave.This indicates the movement of one
tube relative to the other.The time delay between the two sine waves is called Delta-T,and this value is directly proportional to the mass flow rate.In addition,the flow meter has the advantage of a wide measurement range.
(11) Circulation Pump:A 304 stainless steel vortex pump is used.Its impeller is an integral disc with many small blades around its outer edge.The liquid repeatedly moves in a vortex pattern between the blades and the flow passages inside the pump body.The pump features a compact size,high head,low noise,and low destructive impact on contaminants.
4.3 Contaminant Injection System
The contaminant injection system is a patented system developed by our company for the multi-pass test bench.It consists of a contaminant injection oil tank,dispersion device,circulation pump,heat exchanger,heater,temperature sensor,liquid-level sensor,and metering pump.
Its function is to inject a quantitatively controlled amount of high-concentration contaminants into the test system.The dispersion device ensures the uniform distribution of contaminants in the system oil tank,while the metering pump ensures the volumetric accuracy of the contaminants added to the test system,thereby accurately measuring the amount of contaminants injected into the test system.
(1)Pipes and Connectors:The test pipelines and pipe fittings are made of 304 precision stainless steel tubes,with a pressure design margin of≥1.2 times.The inner surfaces of the pipelines are smooth,effectively preventing particulate matter from adhering to them.The pipeline structure is designed to keep the oil in a turbulent state while minimizing dead corners where particulate matter may accumulate.Pipe connections use standard compression-type fittings or flat-face sealed connections.The arrangement of pipe connectors and pipelines avoids flow dead zones,effectively preventing the accumulation of particulate matter.
(2)Contaminant Injection Oil Tank:The contaminant injection oil tank is made of 304 stainless steel and features a conical bottom structure with a cone angle not exceeding 90°.The return oil is ensured to disperse below the oil surface.This design effectively prevents the accumulation of particulate
matter.Liquid-level monitoring and temperature monitoring sensors are installed in the oil tank to monitor the condition of the oil in real time.
(3) Dispersion Device:A patented structural design is adopted to match the contaminant injection oil tank.It can maintain the distribution state and suspension stability of particulate matter at low power consumption,effectively ensuring the uniform mixing of contaminants.This device has been effectively verified on multi-pass test benches,particle counter calibration test benches,and standard material preparation benches.
(4) Circulation Pump:A 304 stainless steel vortex pump is used.Its impeller is an integral disc with many small blades around its outer edge.The liquid repeatedly moves in a vortex pattern between the blades and the flow passages inside the pump body.The pump features a compact size,high head,low noise,and low destructive impact on contaminants.
(5) Metering Pump:A high-pressure plunger metering pump is selected for accurate injection and discharge.This pump is a dedicated metering pump for contaminant injection.Its internal structure is made of ceramic material,providing strong contamination resistance,good stability,and high output accuracy.It can withstand a maximum concentration of 50 g/L in an ISO 12103-A3 dust suspension.This pump has been widely used in airborne contamination monitor calibration devices and particle-counting multi-pass test benches,achieving good results.
(6) Chiller Unit(Optional):An industrial laser chiller unit is selected.It uses compressor-based refrigeration,offering strong cooling capacity,high refrigeration efficiency,and precise temperature control.The chiller has a compact design and is equipped with its own water tank and power pump assembly,effectively ensuring temperature stability during testing.
4.4 Electrical Control System
The electrical control system mainly consists of two parts:hardware and software.The system hardware uses well-known brands in the industry,offers a wide range of applicable operating conditions,and provides reliable operation.
(1) Industrial Computer:A Taiwan Advantech industrial computer is used.This industrial computer system is stable,highly reliable,and offers good software compatibility.The company is a global provider of IoT solutions and embedded industrial computing products.Its business covers industrial automation,smart healthcare,intelligent transportation,and other fields,with branches in 21 countries.Its products are widely used in education,healthcare,transportation,scientific research,military industries,and other fields.
(2) PLC:A German Siemens S7-200smart control system is used.It features flexible module expansion capabilities to accommodate complex application scenarios.The CPU comes standard with an Ethernet interface and supports industrial Ethernet communication protocols.This interface enables communication with the touchscreen,frequency converter,host computer,and other devices,ensuring the timeliness of data acquisition.The control system is stable,highly reliable,and compatible with the Windows operating system.
(3) Frequency Converter:An INVT Goodrive200A series three-phase frequency converter is selected.It controls the pump flow rate by changing the motor operating power supply frequency to meet the test requirements.This frequency converter is a new-generation open-loop vector frequency converter.It uses a DSP control system to integrate torque control and speed control while enhancing reliability and environmental adaptability.It offers anti-tripping performance exceeding that of similar products and has strong adaptability to harsh power grid conditions,temperature,humidity,and dust.INVT is a national key high-tech enterprise,recognized as an enterprise under the National Torch Program and a drafting organization for the national standard for low-voltage frequency converters.Its frequency conversion technology is at the international leading level.
(4) Circuit Breakers and Contactors:The equipment's circuit breakers,contactors,and relays use Schneider products from France or equivalent brands.They offer high reliability and good stability,and their safety and quality have been verified by the market.
(5) Software System:The operating software is proprietary software independently developed by our company.Its interface is simple and easy to understand.The icons change prominently when components operate,and adjustable components display their changing values,making adjustment and observation convenient.The operating software can run automatically according to the set parameters and display the system operating status in real time,including temperature,flow rate,pressure,and other parameters.It also records test data during the testing process and automatically generates a test report after the test is completed.The control system is equipped with an alarm screen and corresponding safety protection measures.It can issue alarms when abnormalities occur and display common causes of errors.During operation,an alarm is triggered when pressure,temperature,or flow rate exceeds the specified limits.The operating software is independently developed by our company,operates stably,and is supported by subsequent upgrades and bug-fixing services.
Leave Message Get Price