Electromagnetic Vibration Test System G-1405

I. Product Description
1.1. The vibration test system is primarily used to conduct vibration and shock environmental tests, environmental stress screening (ESS) tests, and reliability tests on products.
1.2. The electromagnetic vibration testing machine is designed entirely in accordance with relevant battery testing standards. It simulates battery operation under specified vibration test conditions. The battery or battery pack is securely mounted on the vibration table and subjected to vibration along three mutually perpendicular axes of the battery sample according to the specified frequency, acceleration, and displacement modes. During testing, the battery must not leak, release gas, rupture, catch fire, or explode.
II. Application Scope
This machine has an extremely wide range of applications, covering industrial products such as circuit boards, batteries, aircraft, ships, rockets, missiles, automobiles, and household appliances.
III. Applicable Standards
3.1. GB/T 31241-2014 – Safety Requirements for Lithium-Ion Cells and Batteries for Portable Electronic Products
3.2. YDB 032-2009 – Backup Lithium-Ion Battery Packs for Telecommunications
3.3. UL 1642:2012 – Standard for Lithium Batteries (Safety)
3.4. UL 2054:2012 – Standard for Safety of Household and Commercial Batteries (Lithium Batteries)
3.5. UN38.3 (2012) – Recommendations on the Transport of Dangerous Goods – Manual of Tests and Criteria, Part III
3.6. IEC 62133-2:2017 – Safety Requirements for Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes
IV. Vibration System Selection Formula and Vibration Exciter Structural Diagram
4.1. Test Conditions Provided by the User:
4.1.1. Test types: Sinusoidal vibration; random vibration.
4.1.2. Frequency response range: 2–4000 Hz.
4.2. Formulas:
A(g)=(2πf)2Dcm/980≒A=0.002DmmF2 D=A/0.002F2
F=M(kg) ×A(g)

V. System Principle Diagram


VI. Equipment Structural Features
6.1. Vibration Shaker
6.1.1. Armature: The vibration shaker is equipped with a cast and manually machined armature, an optoelectronic pneumatic load support system, and dual-bearing axial guidance. The dual-bearing guidance system is a unique feature that helps reduce axial dynamic cross-motion and rotation during vibration testing, providing superior durability.
6.1.2. Field Coil: Adopts a dual magnetic circuit structure, featuring low magnetic flux leakage and a uniform magnetic field.
6.1.3. Shaker Surface: Advanced phosphating treatment and automotive-grade baking paint technology are adopted to provide long-term wear and rust resistance.
6.1.4. Shaker Cooling: Low-noise fans and an improved air inlet structure are adopted. The field coil uses a honeycomb air duct, while the central magnetic ring adopts a double-layer split-flow air duct. These innovative air duct designs enhance the cooling performance.
6.2. Digital Switching Power Amplifier
The digital switching power amplifier adopts reliable MOSFET or IGBT technology. Key components are supplied by internationally renowned companies, including APT Corporation (USA), Firestone (USA), Mitsubishi (Japan), Hitachi (Japan), and LG (South Korea), ensuring reliable quality.
6.2.1. High stability and reliability.
6.2.2. Complies with EU CE standard requirements.
6.2.3. Adopts sinusoidal pulse-width modulation technology with frequency multiplication, providing a high signal-to-noise ratio.
6.2.4. Operates based on switching power supply principles, achieving high conversion efficiency.
6.2.5. Adopts electronic automatic current-sharing technology.
6.2.6. Excellent safety performance.
6.3. Servo Protection System
The system provides comprehensive protection functions, including protection circuits for grid overvoltage, grid undervoltage, phase loss, logic faults, power module shoot-through, power module overtemperature, output overcurrent, output overvoltage, drive power supply, shaker displacement, shaker temperature, and external interlocks.
6.4. Vertical Expansion Platform
The expansion platform is generally used as a mounting platform for larger test specimens. It can be square, circular, or customized according to user requirements.
To minimize the impact of the expansion platform on dynamic characteristics, the modal frequencies of all expansion platforms must be analyzed through modeling. These expansion platforms are generally made of cast magnesium alloy and fitted with damping materials.
6.5. Automatic Optoelectronic Centering System
Automatically adjusts the armature position to maintain a balanced state. The automatic centering system ensures that the armature remains in the central position throughout the loading and unloading processes.
6.6. Horizontal Slip Table (Optional)
The horizontal slip table is designed with high overturning moment capacity and lateral restraint. This design, combined with a standard horizontal slip table assembly, provides high dynamic moment capacity
while maintaining the damping characteristics of the guiding oil film.
The horizontal slip table consists of a sliding plate, connecting head, natural granite surface plate, horizontal slip table base, and independent oil supply system.
6.7. Introduction to the Digital Vibration Controller
The vibration controller adopts an advanced distributed architecture. Closed-loop control is implemented by a DSP processor, while the PC operates independently outside the control loop, ensuring real-time performance and high efficiency of the control system.
It can respond promptly and rapidly to any changes in the test system, ensuring control stability and high precision.
The hardware features a 32-bit floating-point DSP processor with a clock frequency of up to 300 MHz and 24-bit resolution ADC/DAC. Combined with high-precision floating-point digital filtering and low-noise hardware circuit design technology, the controller achieves a random control dynamic range of more than 90 dB and a signal-to-noise ratio of more than 100 dB.
6.7.1. Features of the Vibration Controller
6.7.1.1. High Performance and Reliability
Closed-loop control is implemented by a DSP processor, while the PC operates independently outside the control loop, ensuring real-time performance and high efficiency of the control system. It can respond promptly and rapidly to any changes in the test system, ensuring control reliability and high precision.
All input channels are equipped with 24-bit resolution ADCs, low-noise hardware design, and built-in analog and digital anti-aliasing filters, effectively ensuring high-precision analysis.
6.7.1.2. Easy Operation
The Windows-based application software is easy to operate and provides comprehensive auxiliary functions.
The system's powerful automatic guidance functions and automatic test report generation make repetitive and tedious testing tasks simple and convenient.
Test parameter settings are comprehensive and precise. In addition, the USB 2.0 interface provides a closer and more convenient connection to the computer.
6.7.1.3. Powerful Functions and Flexibility
The vibration controller is a powerful vibration control platform capable of performing multiple complex tasks.
By configuring different application software on the same hardware platform, it can perform various analysis tasks to meet different testing and analysis requirements.
The controller adopts a modular design, allowing the corresponding hardware and software to be configured according to different user requirements.
6.7.1.4. Test Safety
The controller can provide low-level signal control to preview the vibration control performance of the system. This method helps test engineers determine the noise level in advance and obtain a preliminary understanding of system characteristics, such as the transfer function.
It also provides multiple safety checks and interlock settings to maximize the safety of test personnel, test
specimens, and vibration shaker equipment.If any system abnormality occurs, the test can be terminated immediately by pressing the built-in STOP button.
6.7.1.5. Test Report Generation
Supports one-click generation of test reports in Word or PDF format. Users simply need to click the report generation button to obtain the current test results.
The reports cover all relevant information, from basic test control function descriptions and specific test configuration parameters to control target spectrum curves and test time-domain and frequency-domain curves.
Reports can be conveniently modified and prepared according to different testing report specifications. They also support direct printing, print preview, and online transmission.
6.7.2. Digital Vibration Controller Function Description
6.7.2.1. Random Control
Based on the power spectral density (PSD) profile customized by the user through the target spectrum editor, random control adopts a transfer function equalization method to continuously output Gaussian random signals and rapidly perform accurate, real-time, multi-channel closed-loop control.
The built-in adaptive control algorithm can respond quickly to system nonlinearities, resonance frequency changes, and load variations.
Frequency Range: 0–4800 Hz, expandable to 18750 Hz
Resolution: 100, 200, 400, 800, 1600, 3200 spectral lines
Control Dynamic Range: Greater than 90 dB
Control Strategies: Single-channel control, weighted average, maximum value, minimum value
6.7.2.2. Sine Control
Sine control provides high-quality simulated sinusoidal and sine sweep signals and controls the amplitude of the sine waveform.
Users can set the dwell level and dwell frequency, and determine the dwell duration by setting the time or the number of sine signal cycles.
Frequency Range: 1 Hz–5000 Hz, expandable to 10000 Hz
Closed-Loop Time: 5 ms
Harmonic Distortion: Less than -100 dB
Sweep Modes:
Linear sweep: 0–6000 Hz/min
Logarithmic sweep: 0–100 Oct/min
Sweep Direction: Upward and downward
Sweep Duration: Adjustable by sweep cycles or time
6.7.2.3. Classical Shock
Adopts the transfer function equalization method and supports half-sine, bell-shaped, rectangular, trapezoidal, leading-edge sawtooth, trailing-edge sawtooth, and triangular waveforms.
Users can also enter the pulse peak value as required.
Pulse Duration: 0.5–3000 ms
Maximum Analysis Bandwidth: 22000 Hz
Frame Size: Maximum 16384
Applicable Standards: MIL-STD-810 (U.S. Military Standard), ISO standards, and user-defined interruption control limits.
VII. Technical Specifications
Electromagnetic Vibration Exciter Specifications
Electromagnetic Vibration Exciter Specifications | ||||
Maximum Sine Excitation Force | 300 kgf peak | |||
Maximum Random Excitation Force | 600 kgf rms | |||
Maximum Shock Excitation Force | 600 kgf peak | |||
Frequency Range | 1–2800 Hz | |||
Maximum Displacement | 40 mm p-p | |||
Maximum Velocity | 2 m/s | |||
Maximum Acceleration | 100 G | |||
Maximum Load (Sine) F=M×A | ||||
5 G (50 m/s²) | 10 G (100 m/s²) | 20 G (200 m/s²) | 30 G (300 m/s²) | |
190 kg | 90 kg | 40 kg | 24 kg | |
First-Order Resonance Frequency | 3200 Hz ±5% | |||
Maximum Load M1+M2 | 300 kg | |||
Vibration Isolation Frequency | 2.5 Hz | |||
Armature Diameter | Φ240 mm | |||
Armature Weight | 10 kg | |||
Table Surface Mounting Screws | 17 × M10 | |||
Magnetic Flux Leakage | Less than 1 mT (10 Gauss) | |||
Allowable Eccentric Moment | 500 N·m | |||
Equipment Dimensions | 915 mm × 740 mm × 785 mm (excluding expansion platform) | |||
Equipment Weight | 1100 kg (excluding horizontal slip table) | |||
Digital Switching Power Amplifier
Item | Specification |
Output Power | 10 kVA |
Output Voltage | 100 V |
Output Current | 120 A |
Signal-to-Noise Ratio | Greater than 65 dB |
Power Amplifier Dimensions | 600 mm × 900 mm × 1130 mm |
Servo Protection System
Item | Specification |
Protection Functions | Temperature, air pressure, over-displacement, overvoltage, overcurrent, input undervoltage, external faults, control power supply, logic faults, input phase loss, etc. |
Digital Vibration Controller
Item | Specification |
Hardware Configuration | 2 input channels, 1 output channel Sine, random, classical shock |
Control Computer | Original branded computer equipped with a 17-inch LCD monitor, keyboard, and optical mouse |
Software | Chinese/English operation; supports time-domain and frequency-domain analysis, signal source functions, sine sweep analysis, etc. Automatically generates Word test reports and provides signal and data display, storage, test parameter configuration, and analysis functions. |
Operating System | Windows 10 |
Accelerometer | Frequency Range: 1–12000 Hz Sensitivity: 30 pC/g Temperature Range: -40 to 180°C |
Vertical Expansion Platform
Item | Specification |
Material | Aluminum/Magnesium Alloy, with hard anodized surface treatment |
Dimensions | 400 mm × 400 mm |
Mounting Holes | M8 stainless steel threaded inserts, durable and wear-resistant |
Operating Frequency | 2000 Hz |
Weight | 15 kg |
Cooling Fan (Including Silencer)
Item | Specification |
Fan Power | 4 kW |
Airflow Rate | 18 m³/min |
Electrical Requirements
Item | Specification |
Power Supply | 3-phase, 380 V/50 Hz, 25 kVA |
Compressed Air | 0.6 MPa |
Grounding Resistance | ≤4 Ω |
VIII. Equipment Operating Conditions
8.1. Ambient Temperature: 25 ± 5°C
8.2. Ambient Humidity: ≤65 ± 5% RH
8.3. Power Supply Requirements: 3-phase, AC 380 V/50 Hz, 15 kVA (or as specified according to the destination country), with reliable grounding.
IX. Standard Equipment Configuration upon Delivery
9.1. Main Unit: 1 set
9.2. Product Operation Manual: 1 copy
9.3. Product Warranty Card: 1 copy
9.4. Product Certificate of Conformity: 1 copy
Leave Message Get Price