Structural Integrity Test Bench

1. Overview
In hydraulic transmission systems,filters maintain the cleanliness of fluids by removing insoluble contaminants.To achieve and maintain the required performance level,a filter primarily depends on its filtration ratio and structural integrity,among other parameters.Any structural defects,whether caused during the manufacturing process or resulting from insufficient strength,may cause fluid to bypass the filter,thereby reducing its performance.
For a finished filter element,its structural integrity can be evaluated through non-destructive structural integrity testing.This test determines whether defects exist in the filter element that may allow fluid to bypass during filtration.It can also serve as a quality control method for filter elements.In addition,the test is used to evaluate the filter element's ability to resist damage during actual use and testing.
The Structural Integrity Test Bench developed and manufactured by our company(hereinafter referred to as the"Test Bench")is primarily designed to evaluate the structural integrity of filter elements using non-destructive methods.It is used to determine whether filter elements are damaged during manufacturing,testing,or operation.Measurements of the initial bubble point can also be used to improve product development or evaluate manufacturing processes.
1.1 Design Basis
The Test Bench is designed in accordance with GB/T 14041.1—2007,Hydraulic Fluid Power—Filter Elements—Part 1:Verification of Structural Integrity and Determination of the First Bubble Point.
1.2 Test Items
Determination of the initial bubble point of filter elements
Structural integrity characteristics of filter elements
1.3 Reference Documents
(1)GB/T 786.1-2021,Hydraulic Fluid Power Systems and Components—Graphical Symbols and Circuit Diagrams—Part 1:Graphical Symbols
(2)GB/T 3766-2015,Hydraulic Fluid Power—General Rules and Safety Requirements for Systems and Their Components
(3)GB/T 7935-2005,Hydraulic Fluid Power Components—General Technical Specifications
(4)GB/T 5226.1-2019,Electrical Safety of Machinery—Electrical Equipment of Machines—Part 1:General Requirements
(5)ISO 2942:2018,Hydraulic Fluid Power—Filter Elements—Part 1:Verification of Structural Integrity and Determination of the First Bubble Point
(6)GB/T 14041.1-007,Hydraulic Fluid Power—Filter Elements—Part 1:Verification of Structural Integrity and Determination of the First Bubble Point
1.4 Technical Features
(1)The Test Bench adopts an enclosed design,with an industrial aluminum profile frame featuring high strength,an attractive appearance,and other advantages.
(2)The equipment uses an external air supply for testing,with a supply pressure of 0.2–0.8 MPa.A filter is installed at the equipment's air inlet to purify the test gas.
(3)The test liquid may become contaminated after prolonged use,thereby affecting the test results of the products being tested.The equipment is equipped with a liquid storage tank,purification filter,and liquid filling and draining devices.These components enable system purification,liquid filling and purification,and liquid draining and purification,effectively ensuring the cleanliness of the test liquid.
(4)The equipment is equipped with a semi-automatic filter element clamping fixture and an automatic rotation mechanism,enabling filter elements to be quickly clamped and tested.The rotational speed of the filter element can be adjusted as required.
(5)The equipment features a filter element drying function.After testing,the filter element can be quickly dried.The drying pressure can be adjusted according to the pressure resistance of the filter element to prevent damage.
(6)The equipment features a user-friendly human-machine interface,a high degree of automation,and simple operation.The program can collect and display test pressure(bubble point value),test flow rate,and immersion depth in real time,and display the bubble point test results.After the data is saved,it can be exported to external devices through a data interface.
(7)The Test Bench is equipped with comprehensive safety protection measures,including mechanical protection and electrical alarm functions,as well as electrical interlocking and overload protection.
2. Main Technical Specifications
2.1 Operating Environmental Conditions
(1)Ambient temperature:0°C–40°C;
(2)Ambient humidity:20%–70%;
(3)Power supply:AC 220 V/50 Hz.
2.2 Main Technical Specifications
No. | Technical Parameter | Technical Specification | Remarks |
1 | Test medium | Industrial ethanol(recommended)or isopropanol | |
2 | Test medium | Clean compressed air | |
3 | Ambient temperature | 22±5°C | |
4 | Test filter element diameter | Φ30–φ150 mm | |
5 | Test filter element length | 60–600 mm | |
6 | Test tank dimensions | 800 mm×300 mm×300 mm | |
7 | Test pressure | 15,000 Pa | ±0.25%FS |
8 | Filter element rotational speed | 0–10 rpm | |
9 | Resolution | 1 Pa | |
10 | Pore size test range | 3–100μm | |
11 | External power supply | AC 220 V/50 Hz | |
12 | External air supply | 0.4–0.8 MPa | |
13 | Equipment power | 1.5 kW | |
14 | Overall dimensions | 2000×1000×2000(L×W×H) | Subject to the approved drawing |
15 | Weight | 800 kg |
3. Working Principle
①Pressure-regulating filter | ⑦On/off solenoid valve | ⑬On/off ball valve |
②Precision pressure regulator | ⑧Rotation mechanism | ⑭Liquid storage tank |
③Throttle valve | ⑨Lifting mechanism | ⑮Three-way ball valve |
④Silencer | ⑩Liquid level switch | ⑯Liquid transfer pump |
⑤Two-position,three-way valve | ⑪Test specimen | ⑰Purification filter |
⑥Pressure sensor | ⑫Test liquid tank |
4. Design Description
The Test Bench consists of several main sections,including the equipment frame,testing system,hydraulic control system,motion system,and electrical control system.
4.1 Equipment Frame
The main frame of the equipment is made of aluminum profiles,featuring high strength,an attractive appearance,and other advantages.Both the test panel and worktable surface are made of 304 stainless steel plates.
Heavy-duty adjustable mobile casters are installed at the bottom of the equipment frame,allowing the equipment to be moved easily,fixed in position,and leveled.
The equipment is designed with a pull-out liquid collection tray to collect any leaking or dripping test medium and facilitate cleaning.
4.2 Testing System
The testing system mainly consists of a pressure-regulating filter,pressure switch,precision pressure regulator,test tank,pressure sensor,and other components.
When the test liquid fills the gaps between the filter material fibers,clean air is slowly introduced and pressurized from the opposite end.At the instant when the gas displaces the liquid in the pores,the gas pressure equals the opposing surface tension of the liquid(including the effect of the liquid level height).The pressure at which the first continuous stream of bubbles emerges is defined as the initial bubble point pressure.
(1) Pressure-Regulating Filter:An internationally recognized brand of pressure-regulating filter is used to filter and stabilize the pressure of the gas entering the system.The filtration accuracy reaches 5μm.
(1) Pressure Switch:The equipment is equipped with a pressure switch from an internationally recognized brand.When the pressure is insufficient,an alarm is triggered to indicate the cause.
(2) Precision Pressure Regulator:An imported-brand pressure regulator is used to stabilize the inlet pressure of the product,ensuring the stability of the test air supply.
(3) Precision Pressure Regulator:Our company has independently developed a pressure-reducing valve specifically for low-pressure testing,with a control accuracy of±50 Pa,enabling precise control of the test pressure.
(4) Test Tank:The tank is welded from 304 stainless steel,providing high structural strength and excellent corrosion resistance.
(5) Pressure Sensor:A monocrystalline silicon pressure sensor is used,offering high measurement accuracy and good stability.The sensor supports the HART protocol,making adjustment and configuration convenient and efficient.
4.3 Hydraulic Control System
The hydraulic control system mainly consists of a liquid storage tank,liquid transfer pump,directional control valve,precision filter,pipes,fittings,and other components.
Its primary function is to supply test liquid to the test tank at the beginning of the test and adjust the liquid level to meet testing requirements.After testing,the test liquid is collected in the liquid storage tank for long-term storage.
(1) Liquid Storage Tank:The tank is welded from 304 stainless steel and has a sandblasted surface finish.It adopts a sealed structural design to effectively prevent evaporation losses during long-term storage of the test liquid.A liquid level indicator is provided for convenient monitoring of the liquid level.
(2) Liquid Transfer Pump:A stainless steel centrifugal pump is used.It features low noise and high delivery head,ensuring stable flow output even when the filter element is clogged.
(3) Directional Control Valve:A sanitary-grade pneumatic three-way valve is used.The valve body is made of 304 stainless steel,and the valve seat is made of PTFE,providing good compatibility.The valve adopts an integrated structural design and is actuated by a pneumatic actuator.It features fast response,compact size,reliable performance,simple integration,and high flow capacity.
(4)Precision Filter:The filter is made of 304 stainless steel and contains a high-precision purification filter element.Its filtration efficiency for particles of 4μm reaches 99.9%,effectively ensuring system cleanliness.
(5)Pipes and Fittings:The test pipelines and fittings are made of precision 304 stainless steel tubing,with a pressure design margin of at least 1.2 times.The inner surfaces of the pipelines are smooth,effectively preventing particle adhesion.Standard clamp-type connections are used for pipe fittings.The layout of the fittings and pipelines is designed to avoid flow dead zones and effectively prevent particle accumulation.
4.4 Motion System
The motion system mainly consists of a clamping mechanism,lifting mechanism,and rotation mechanism.It is primarily used to secure and clamp the test specimen,raise and lower it for immersion,and rotate it during testing for observation.
(1)Clamping Mechanism:A cantilever structure is adopted,with a cylinder and guide rail used for precise positioning.The sealing section of the filter element clamping mechanism features a quick-change design,allowing fixtures to be quickly replaced according to different filter element specifications.
(2)Lifting Mechanism:A lead screw assembly combined with a variable-speed motor is used to control the vertical movement of the product.A liquid level sensor precisely controls the immersion depth of the product.During testing,the position is adjusted in real time according to changes in the liquid level.
(3)Rotation Mechanism:A variable-speed motor and transmission mechanism are used to automatically rotate the filter element during testing,allowing the bubble point position to be observed.The rotation mechanism features adjustable rotational speed and selectable rotation direction.
4.5 Electrical Control System
The electrical control system mainly consists of two parts:hardware and software.The system hardware uses well-known industry brands and is suitable for a wide range of operating conditions,ensuring reliable operation.
The control system adopts a patented microcomputer touchscreen control system,featuring simple operation,stable performance,and other advantages.
(1) Touchscreen:A Kunlun Tongtai touchscreen is used.The touchscreen system offers stable operation,high reliability,and good software compatibility.The company operates in industrial automation,smart healthcare,intelligent transportation,and other fields.Its products are widely used in education,healthcare,transportation,scientific research,military industries,and other sectors.
(2) PLC:A German Siemens S7-200smart control system is used,featuring flexible module expansion capabilities to accommodate complex application scenarios.The CPU comes standard with an Ethernet interface and supports industrial Ethernet communication protocols.This interface enables communication with the touchscreen,frequency converter,host computer,and other devices,ensuring timely data acquisition.The control system offers stable operation,high reliability,and compatibility with the Windows operating system.
(3) Circuit Breakers and Contactors:The equipment's circuit breakers,contactors,and relays use products from Schneider Electric of France or equivalent brands,offering high reliability and stable performance.Their safety and quality have been verified through market use.
(4)Software System:The operating software is independently developed by our company.Its interface is simple and easy to understand.Icons change visibly when components are activated,making operation and monitoring convenient.
The operating software can run automatically according to preset parameters and display the system operating status,including temperature,pressure,and other parameters,in real time.It also records test data throughout the testing process.
The control system is equipped with alarm screens and corresponding safety protection measures.It can issue alarms under abnormal conditions and display common error causes.
The operating software is independently developed by our company,ensuring stable operation,with subsequent upgrades and bug-fixing services available.
4.6 Safety
(1)The equipment is equipped with an alarm light and provides alarms and protection against overpressure,overload,and electrical leakage,as well as abnormal-condition alarms and self-protection functions,helping prevent accidents and ensuring safe equipment operation.
(2)Signal devices or warning signs are installed on the exterior of the equipment to alert or remind operators to exercise caution.Protective doors are installed around the equipment to prevent accidents caused by incorrect operation and ensure operator safety.An emergency stop button is installed on the
front control panel to enable emergency shutdown in unexpected situations,minimizing losses in the event of an emergency and effectively protecting operators.
(3)A movable liquid collection tray is installed at the bottom of the Test Bench to effectively prevent environmental contamination caused by leakage or dripping.The equipment's pipelines and fittings are made of 304 stainless steel,providing excellent wear resistance and corrosion resistance.
Leave Message Get Price