Thermal Conductivity Tester (Heat Flow Method, Standard Model)

Thermal Conductivity Tester (Heat Flow Method, Standard Model)

The Thermal Conductivity Tester (Heat Flow Method, Standard Model) is a laboratory instrument designed to measure thermal conductivity, thermal resistance, and interface contact thermal resistance of solid materials. It is suitable for thin thermally conductive materials, electrical insulation materials, ceramics, elastomers, and composite materials. With dedicated sample holders, the instrument can also test paste-like and powdered materials under controlled pressure conditions.

Application

The Thermal Conductivity Tester is used for thermal performance evaluation in the following areas:

Thermal conductivity and thermal resistance characterization of solid materials

Interface contact thermal resistance analysis of layered or bonded structures

Heat dissipation and insulation performance testing of electronic materials

Material thermal analysis in universities, research institutes, quality inspection agencies, and industrial laboratories

Applicable materials include thermally conductive silicone pads, greases, resins, rubber, beryllium oxide ceramics, aluminum oxide ceramics, electrical insulation sheets, and composite materials.

Standards

MIL-I-49456A Thermal and Insulating Materials for Thin Sheets, Thermally Conductive Resins, and Glass Fiber Reinforced Composites

GB 5598-85 Method for Measuring Thermal Conductivity of Beryllium Oxide Ceramics

ASTM D5470-12 Standard Test Method for Thermal Transmission Properties of Thin Thermally Conductive Solid Electrical Insulation Materials

Parameters

Parameter Specification
Sample diameter Φ30 mm
Sample thickness 0.02–20 mm
Hot plate temperature range Ambient to 99.99 °C, resolution 0.01 °C
Cold plate temperature range 0–99.0 °C, resolution 0.01 °C
Thermal conductivity range 0.10–45 W/m·K
Thermal conductivity display Up to 4 decimal places
Thermal resistance range 0.05–0.000005 m²·K/W
Pressure measurement range 0–1000 N
Displacement measurement range 0–30.00 mm
Measurement accuracy Better than ±3%
Test modes Thermal resistance under pressure variation; material thermal conductivity; contact thermal resistance; aluminum-based composite thermal resistance; aging and reliability testing
Automation Fully automatic, computer-controlled, data printing supported
Power supply AC 220 V, 50 Hz

Features

Fully automatic pressure loading and sample thickness measurement

Integrated computer control with real-time data acquisition and analysis

Six-point temperature gradient detection improves measurement accuracy

Supports thermal resistance measurement under variable pressure conditions

Optimized calculation models for thermal conductivity, thermal resistance, and interface contact resistance

Compatible with solid, paste, and powder samples

Stable, repeatable, and automated testing process

Accessories

Thermal conductivity tester main unit (no ice required) × 1

Test and control software with communication interface × 1

Constant temperature water bath with controller × 1

Gel and paste sample holders × 2

Control and data acquisition computer × 1

Test Procedures

Prepare the sample according to thickness and surface flatness requirements.

Place the sample between the hot and cold plates using the appropriate holder.

Set the test mode, temperature conditions, and pressure parameters via the control software.

Start the test; the system automatically applies pressure and records temperature gradients.

The software calculates thermal conductivity, thermal resistance, or interface contact resistance.

Save, print, or export test results after completion.

Maintenance Information

Keep the hot and cold plate surfaces clean and free from contamination.

Regularly inspect pressure sensors and displacement sensors for accuracy.

Verify temperature calibration periodically using standard reference materials.

Drain and maintain the constant temperature water bath according to operating guidelines.

FAQ

What is this product?

It is a laboratory instrument designed to measure thermal conductivity, thermal resistance, and contact thermal resistance of materials using the heat flow method.

What is this product used for?

It is used to evaluate heat transfer performance of materials and interfaces, particularly for insulation, heat dissipation, and electronic thermal management applications.

Why is this product important?

Accurate thermal property data is essential for material selection, product design, and reliability assessment in electronics and thermal engineering applications.

What industries is this product suitable for?

It is suitable for electronics, materials science, ceramics, insulation materials, research institutions, quality inspection laboratories, and industrial R&D centers.

What types of this product are available?

The product is available in standard configurations with optional fixtures and software functions to support different materials, pressure ranges, and testing requirements.


Note:QINSUN is very in place for textile testing and quality control,we have our own textile testing lab. Our textile testing equipment and testing methods are in the leading position in the industry. We have passed the textile testing certification and iso textile testing standards issued by a number of testing,We can provide textile testing equipment pdf manual. Sufficient inventory, big discounts, limited time promotion, Order now!

Leave Message Get Price