What is ASTM E119 and ANSI UL 263 test standards?
ASTM E119 and ANSI/UL 263 are test standards used to evaluate the fire resistance performance of building materials and assemblies. These standards determine the ability of materials and assemblies to withstand fire exposure for a specified period of time. Here's a detailed explanation of ASTM E119 and ANSI/UL 263 test standards:
ASTM E119:
ASTM E119 is a test standard developed by ASTM International, a globally recognized organization that develops and publishes technical standards. The purpose of ASTM E119 is to evaluate the fire resistance of building materials, components, and assemblies. The test measures the ability of these materials to maintain their structural integrity, insulation, and smoke barrier properties when exposed to fire. Here are the key features of ASTM E119:
1. Fire Exposure Conditions:
- ASTM E119 uses a standard fire exposure curve known as the "Standard Time-Temperature Curve." This curve represents the time-temperature relationship that a fire typically follows.
- The standard fire exposure conditions specified in ASTM E119 simulate a typical fire scenario, with controlled temperature rise and fire duration.
2. Test Parameters:
- The test measures the time duration for which the test specimen can maintain its structural stability, insulation, and smoke barrier properties.
- The test specimen is exposed to fire on one side, while the other side remains unexposed to fire. The performance of the specimen is evaluated based on various criteria, such as temperature rise, flame passage, structural integrity, and smoke penetration.
3. Test Duration:
- The test duration for ASTM E119 varies depending on the required fire resistance rating. Common test durations include 1 hour, 2 hours, 3 hours, and longer durations.
- The duration represents the time for which the specimen is exposed to fire, and it determines the fire resistance rating assigned to the material or assembly.
4. Test Setup:
- ASTM E119 tests are typically conducted on full-scale assemblies or representative sections of the building, including walls, floors, columns, and roofs.
- The test specimens are installed according to specific guidelines, ensuring proper construction detailing and sealing as per the intended application.
5. Performance Criteria:
- The performance of the test specimen is evaluated based on several criteria, including the maintenance of structural stability, prevention of flame passage, limitation of temperature rise on the unexposed side, and control of smoke penetration.
- The specimen must meet specific performance requirements to achieve a designated fire resistance rating.
6. Test Report and Certification:
- The results of the ASTM E119 test are documented in a test report that specifies the fire resistance rating achieved by the tested material or assembly.
- The test report serves as a basis for certification and code compliance, and it is often used by regulatory authorities and building professionals to verify the fire resistance performance of materials and assemblies.
ANSI/UL 263 (Underwriters Laboratories):
ANSI/UL 263 is a test standard developed and maintained by Underwriters Laboratories (UL), an independent third-party certification organization that specializes in product safety testing and certification. ANSI/UL 263 is also known as the "Standard for Fire Tests of Building Construction and Materials." Here are the key features of ANSI/UL 263:
1. Fire Exposure Conditions:
- ANSI/UL 263 uses a standard fire exposure curve known as the "Standard Time-Temperature Curve" or the "Fire Endurance Curve." This curve represents the time-temperature relationship that a fire typically follows.
- The fire exposure conditions specified in ANSI/UL 263 simulate a realistic fire scenario, considering the development and progression of fire in a building.
2. Test Parameters:
- The test evaluates the ability of building assemblies, such as walls, floors, and ceilings, to resist fire spread and maintain their structural integrity during a specified fire exposure period.
- The performance of the test specimen is assessed based on criteria such as fire resistance, flame spread, smoke generation, temperature rise, and the integrity of the assembly.
3. Test Duration:
- ANSI/UL 263 tests are typically conducted for a duration of 1 hour, 2 hours, 3 hours, or longer, depending on the desired fire resistance rating.
- The duration represents the time for which the test specimen is subjected to fire exposure, and it determines the fire resistance rating assigned to the assembly.
4. Test Setup:
- The test specimens for ANSI/UL 263 are typically full-scale assemblies, representing actual building components such as walls, floors, and ceilings.
- The test setup may include additional components and construction details, such as seals, joints, and penetrations, to simulate real-world conditions.
5. Performance Criteria:
- The performance of the test specimen is evaluated based on several criteria, including fire resistance, flame spread, smoke generation, temperature rise on the unexposed side, and the integrity of the assembly.
- The specimen must meet specific performance requirements to achieve a designated fire resistance rating.
6. Test Report and Certification:
- The results of the ANSI/UL 263 testare documented in a test report provided by Underwriters Laboratories (UL). The test report specifies the fire resistance rating achieved by the tested assembly or material.
- UL certification is widely recognized and accepted as a mark of product safety and performance. Manufacturers often seek UL certification to demonstrate that their products meet the required fire resistance standards.
Both ASTM E119 and ANSI/UL 263 are important test standards used for evaluating the fire resistance performance of building materials and assemblies. They provide valuable information for architects, engineers, regulators, and building owners to make informed decisions regarding fire safety and code compliance. It's essential to consult the specific requirements and regulations applicable to your region or project to ensure compliance with local standards.
2023-11-23 11:41
- Related News
Paper ring compression strength tester standards
Rubber and plastic tensile tester standards
Taber 1750 wear-resistant tester standards
Stone Chip Resistance Gravelometer standards
Diaper absorption speed tester standards
Diaper leakage tester technical indicators
Paint film impact resistance tester standards