Why do mattresses have to be fire-resistant? What is the flammability test standard?
Why do mattresses have to be fire-resistant?
Mattresses are required to be fire-resistant for safety reasons. Fires can spread rapidly, and a mattress that is not fire-resistant can contribute to the rapid spread of fire within a room or building. Improving the fire resistance of mattresses helps to minimize the potential for fires to start or escalate, protecting lives and property.
There are several reasons why mattresses can pose a fire hazard. One primary factor is the materials used in their construction. Many mattresses contain highly flammable materials such as foam and fabric. These materials can ignite easily and burn quickly, releasing toxic gases and smoke that can be harmful or lethal to occupants in a fire situation.

Additionally, mattresses are often located in bedrooms where people sleep for extended periods. This increases the risk of fire incidents occurring when individuals may be less responsive or awakened by a fire. A fire-resistant mattress can provide valuable time for individuals to escape or be rescued in the event of a fire.
To address these concerns, regulations and standards have been established to ensure that mattresses meet certain fire safety criteria. These regulations vary across different countries and regions, but they generally focus on reducing the flammability of mattresses and limiting the potential for ignition, flame spread, and smoke production.
What is the flammability test standard?
Flammability test standards outline the specific requirements and procedures for evaluating the fire resistance of mattresses. These standards provide a standardized framework for manufacturers, regulators, and consumers to assess the performance of mattresses in fire scenarios.
One widely recognized flammability test standard for mattresses is the "California Technical Bulletin 117" (TB 117), which was developed by the California Bureau of Electronic and Appliance Repair, Home Furnishings, and Thermal Insulation (BEARHFTI). TB 117 sets requirements for the resistance of mattresses to ignition by smoldering cigarettes, as well as testing procedures for measuring the rate of heat release from a burning mattress.
In recent years, there has been an update to the flammability test standard in California. The new standard, known as TB 117-2013, focuses on reducing the use of flame retardant chemicals in mattresses while maintaining fire safety. This updated standard requires that mattresses meet specific performance criteria regarding the smolder resistance of covers, barrier materials, and resilient filling materials.
Internationally, another widely adopted flammability test standard for mattresses is the European Standard EN 597. This standard includes two parts: EN 597-1 and EN 597-2. EN 597-1 evaluates the resistance of mattresses to ignition by a small flame, while EN 597-2 assesses the ignitability of mattresses by smoldering cigarettes.
These are just a few examples of flammability test standards for mattresses. Other countries may have their own specific standards or have adopted variations of these standards. It is essential for manufacturers and consumers to be aware of the specific flammability requirements and test methods applicable to their respective regions to ensure compliance with safety regulations.
In conclusion, mattresses need to be fire-resistant to minimize the risk of fire incidents and to protect lives and property. Flammability test standards provide the necessary guidelines and procedures for assessing the fire resistance of mattresses. Compliance with these standards is crucial for manufacturers to ensure the safety of their products and for consumers to make informed decisions about the mattresses they purchase.