Mask Synthetic Blood Penetration Tester

Mask Synthetic Blood Penetration Tester
Medical Face Mask Synthetic Blood Penetration Resistance Tester

Medical masks synthetic blood penetration tester is used to determine the resistance of medical protective masks to penetration by synthetic blood at different test pressures,and can also be used to determine the resistance to blood penetration of other coating materials.

Application
 
Mask synthetic blood penetration tester is used for anti-synthetic blood penetration of medical surgical masks, and mainly used in the field of medical protection products. It can also be used for other textile coating material determination.

Blood penetration resistance tester Standards:

GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood.
YY/T 0691-2008 Clothing for protection against infectious agents-Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)  
YY 0469-2011 Technical requirements of medical face masks– Blood penetration test apparatus.
ISO 226092004 Clothing for protection against infectious agents - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)  
ASTM F1862-07Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Know Velocity)

parameter:
Items Parameters
Injection distance 300mm~305mm, adjustable
Nozzle diameter 0.84mm
Jet velocity 450cm/s,550cm/s,635cm/s
 
1.The protruding sample fixture can simulate the actual use condition of the mask. Reserve the test target area without destroying the sample, and   distribute synthetic blood in the sample target area.
2.A special jet device with constant pressure can spray a certain volume of synthetic blood in a controlled time.
3.It can fully simulate the corresponding injection rate to test under the average blood pressure of the human body at 10.6kPa, 16kPa, 21.3kPa.
4.The fixed target plate can block the high pressure part of the injected liquid flow to allow the steady flow to be sprayed to the sample, increasing the accuracy and repeatability of liquid spraying speed.


Note:QINSUN always been committed to innovation and improve product performance and functionality, based on the reasons, the product specifications will be changed accordingly. The above without prior notice, the Company reserves the right to amend the final.
Qinsun Instruments Co., LTD
Unified national hotline:021-64200566
> Mask Synthetic Blood Penetration Tester RFQ
*name:
*company:
*email:
*telephone:
content:
*Security Code:  See? Click to changeSee? Click to change
Qinsun Instruments Co., LTD
Unified national hotline:021-64200566
> Mask Synthetic Blood Penetration Tester RFQ
*name:
*company:
*email:
*telephone:
content:
*Security Code:  See? Click to changeSee? Click to change